I finally got my printer working again. I spent the whole day going through Teaching Tech’s calibration steps. All the flat calibration gcode looks fine. The Benchies are another problem though. I’m printing with a 0.6mm nozzle for the first time.

On the smaller benchy I printed at 0.2 layer height, with a perimeter speed of 40mm/s at 210/60 temps. The bigger one is 110% larger and printed at 0.25 layer height, with a perimeter speed of 60mm/s at 215/60 C.

The problems are mostly manifested in the same area. Big blobs in the rear and layer shifting on the tail pipe. Large layer shifts/bulges in the center. I’ve never really ran into this problem before so I don’t know where to start when diagnosing this.

  • puppetx@lemmy.world
    link
    fedilink
    English
    arrow-up
    1
    ·
    1 year ago

    If you look at the sliced tool paths, what is it doing when it puts those Xs into your test print?

      • sneakyninjapants@sh.itjust.works
        link
        fedilink
        English
        arrow-up
        1
        ·
        edit-2
        1 year ago

        The area where it’s layer shifting in the center of the boat, if you have some way of measuring that, divide by layer height to determine what layer that happened between. If the slicer is doing anything fucky with the tool paths than that may be a contributing factor.

        Edit: Sorry, just realized that puppetx was talking about the box, not the boat

      • puppetx@lemmy.world
        link
        fedilink
        English
        arrow-up
        1
        ·
        1 year ago

        In prusa slicer after you click slice you will be presented with your sliced gcode. At this point you can use the vertical scroll bar on the right (to pick a layer), and the horizontal scroll bar on the bottom (to play through the tool path (moves) for that layer) to see every operation your printer is going to perform as it runs this gcode.

        If this was somehow caused by bad slicing/g-code it could be used to help troubleshoot it. But it sounds like others here have probably provided more insightful troubleshooting suggestions and you may want to pursue their advice first. Hopefully your tightened z screw solves the problem!