I have created this climate:

- name: "Riscaldamento"
  unique_id: "termostato"
  modes:
    - "off"
    - "heat"
    - "cool"
  mode_command_topic: "home/riscaldamento_raffrescamento/TEST/mode/set"
  mode_state_topic: "home/riscaldamento_raffrescamento/TEST/mode/state"
  temperature_command_topic: "home/riscaldamento_raffrescamento/TEST/temp/set"
  current_temperature_topic: "home/riscaldamento_raffrescamento/TEST/temp/state"
  power_command_topic: "home/riscaldamento_raffrescamento/TEST/pump/set"
  payload_on: 1 
  payload_off: 0
  min_temp: 17
  max_temp: 28
  temp_step: 0.1
  precision: 0.1

thinking that the power_command_topic would be sent whenever the temperature would go over/under the one set, but nothing ever get send to that topic. How can I turn on the pump when the temperature goes under the one set and turn it off when it goes over?

  • paf@jlai.lu
    link
    fedilink
    English
    arrow-up
    1
    ·
    8 months ago

    here is my config yaml for climate. added hint for your case but i never had heat pump, does your heat pump only heat or does it also cool? exemple here is ok if only heat. If yours heat/cool, try some of the hacs thermostat addon. A quick search led me to this https://community.home-assistant.io/t/generic-thermostat-switch-between-heating-and-cooling/420053 which point to https://github.com/swingerman/ha-dual-smart-thermostat but i know they are more hacs addon for thermostat, you may need to search which is good for your use if the one above doesn’t suit your needs

    climate:
      - platform: generic_thermostat
        name: Thermostat Chambre (Riscaldamento)
        heater: switch.radiateur_chambre (device to toggle your heat pump)
        target_sensor: sensor.sonde_chambre_temperature (your temp sensor)
        min_temp: 12
        max_temp: 21
        ac_mode: false
        target_temp: 19
        cold_tolerance: 0
        hot_tolerance: 0.1
        min_cycle_duration:
          seconds: 300
        keep_alive:
          minutes: 3
        initial_hvac_mode: "off" (set this to heat if you want it to be active when HA start/reboot)
        away_temp: 12
        precision: 0.1
    
    • peregus@lemmy.worldOP
      link
      fedilink
      English
      arrow-up
      1
      ·
      edit-2
      4 months ago

      I’m trying to use the generic thermostat:

      climate:
        - platform: generic_thermostat
          name: termostato_raffreddamento
          heater: switch.valvola_climatizzazione
          target_sensor: sensor.aqara_temp_sala_temperature
          min_temp: 24
          max_temp: 28
          ac_mode: true
          target_temp: 26 
          cold_tolerance: 0.1
          hot_tolerance: 0.1
          min_cycle_duration:
            seconds: 300
          keep_alive:
            minutes: 3
          initial_hvac_mode: "off"
          away_temp: 28
          precision: 0.1
      

      But I only have the button to turn it off:

      If I click it nothing happens. What have I done wrong?

      • paf@jlai.lu
        link
        fedilink
        English
        arrow-up
        2
        ·
        edit-2
        4 months ago

        on your card, click on the three dots. You should have more options there. If it doesn’t work, change “intial_hvac_mode” to “cool”

        edit: didn’t see your next replied, glad you work it out

      • peregus@lemmy.worldOP
        link
        fedilink
        English
        arrow-up
        1
        ·
        4 months ago

        I remove the feature “Climate HVAC mode” and added it again and now I can use it.